When in a plant is available steam with high pressure and temperature, it can be used to feed steam turbines that provide power for fans and blowers. Usually also an electric motor is added as back-up driver when steam is not available for any reason. This situation is the typical background for a Dual Drive solution.
1. capacities up to 1.600.000 m3/h
2. static pressure up to 200 mmH2O
3. installed power up to 650 kW
Advantage: - Axial fans VAO can reach static efficiency up to 70%. - Maximum temperature of continuously operating (impeller only) is 150 °C. - The casing are protected by hot dip galvanisation in accordance with UNI 5744-66.
When in a plant is available steam with high pressure and temperature, it can be used to feed steam turbines that provide power for fans and blowers. Usually also an electric motor is added as back-up driver when steam is not available for any reason. This situation is the typical background for a Dual Drive solution.
MULTI-STAGE CENTRIFUGAL FANS/BLOWERS
Products
Since 1928 , care about environment!
OUR PARTNERS
Aeromeccanica Stranich
Industrial Ventilation and Dust Control
AEROMECCANICA STRANICH started its own activity in 1928, with the engineering, manufacturing and installation of centrifugal fans, axial fans and dampers for all the industrial applications, acquiring and keeping over the years, a leading position in the field. Since 1970 the Company developed the interest in the field of systems for pollutant and dusty gases control; on this purpose a structure has been specifically created for the engineering, manufacturing and installation of quipments such as wet and dry filters, cyclones, scrubbers and pneumatic cleaning and conveying systems, always trying to propose technologically advanced solutions, realized on the base of own licenses, or as a result of the cooperation with the leading Companies in the field, based in Europe and all over the world, achieving a role of excellence also in the pollution control field.
Industrial Ventilation
• HIGH PRESSURE MULTISTAGE CENTRIFUGAL Blowers
• HIGH PRESSURE CENTRIFUGAL FANS
• HIGH FLOWRATE CENTRIFUGAL FANS
• HEAVY DUST CONTENT CENTRIFUGAL FANS
• AXIAL FANS
• FANS AND BLOWERS ACCESSORIES Dust control
• HIGH PRESSURE BAG FILTERS
• HIGH PRESSURE & TEMPERATURE CYCLONES
• BAG FILTERS
• CARTRIDGE FILTERS
• CYCLONES
• SCRUBBERS
The centrifugal fans bcsn, bcfn and tss series have been designed to convey air or gas with a maximum concentration of dust of 100 mg/nm³ (bcsn/bcfn) or 500 mg/nm³ (tss), they can be installed in:
• De-dusting,
• Process air drying,
• Fumes extraction,
• Industrial air conditioning,
• Waste incineration systems,
• Reformer,
• Boiler & Furnaces,
Our Fans & Blowers capacities can reach up to 2,000,000 m³/h, static pressure up to 10,000 mmh2o (depend on application) and installed power of 8,000 kw. The impeller of bcsn series has airfoil blades, the bcfn one has flat blades backwardly inclined and the tss one has curved blades backwardly.
1. volumetric flowrate up to 10.000 m3/h
2. static pressure up to 9.000 mmH2O (multi-stage) and 2.500 mmH2O (single stage)
3.installed power up to 350 kW
Advantage:
-Impeller is best suited for fluid with dusts maximum concentration of 200 mg/Nm3. Highest Efficiency up to 75%
ABD SERIES
TR SERIES
1. volumetric flowrate up to 300.000 m3/h
2. static pressure up to 800 mmH2O
3. installed power up to 1000 kW
Advantage: -Suitable for very dusty and abrasive fluid -Impeller is best suited for fluid with dusts maximum concentration of 30 g/Nm3. -Highest Efficiency up to 72%
TSS SERIES
1. volumetric flowrate up to 350.000 m3/h
2. static pressure up to 1000 mmH2O
3. installed power up to 900 kW
Advantage: -Static efficiencies of 73% are obtained and noise levels are kept to a minimum. -The TSS impeller is best suited for fluid with dusts maximum concentration of 200 mg/Nm3.
TS SERIES
1. volumetric flowrate up to 250.000 m3/h
2. static pressure up to 1400 mmH2O
3. installed power up to 1000 kW
Advantage: -Static efficiencies of 76% are obtained and noise levels are kept to a minimum. -The TS impeller is best suited for fluid with dusts maximum concentration of 200 mg/Nm3.
H-HR-HS SERIES
K-KR SERIES
1. volumetric flowrate up to 250.000 m3/h for H series, 150.000 m3/h for HR series and 100.000 m3/h for HS series
2. static pressure up to 2.000 mmH2O
3. installed power up to 2.000 kW for H series and 1000 kW for HR and HS series Advantage: -The H-HR-HS impeller is best suited for fluid with dusts maximum concentration of 200 mg/Nm3.
BCFN SERIES
1. volumetric flowrate up to 700.000 m3/h
2. static pressure up to 600 mmH2O
3. installed power up to 800 kW
Advantage: - Static efficiencies of 78% are obtained and noise levels are kept to a minimum. -The BCFN impeller is best suited for fluid with dusts maximum concentration of 500 mg/Nm3.
1. volumetric flowrate up to 500.000 m3/h
2. static pressure up to 1.850 mmH2O
3. installed power up to 2.000 kW
Advantage: - Static efficiencies of 82% are obtained and noise levels are kept to a minimum. -The TSAN impeller is best suited for fluid with dusts maximum concentration of 100 mg/Nm3.
TSAN SERIES
1. volumetric flowrate up to 200.000 m3/h for K series and 120.000 m3/h for KR series
2. static pressure up to 1.850 mmH2O
3.installed power up to 1.000 kW for K series and 800 kW for KR series
Advantage: -Static efficiencies of 80% are obtained and noise levels are kept to a minimum. -The K-KR impeller is best suited for fluid with dusts maximum concentration of 100 mg/Nm3.
BDC SERIES
BCSN SERIES
HP SERIES
DUAL DRIVE CENTRIFUGAL FANS/BLOWERS
DAMPERS AND ACCESORIES FOR FANS AND BLOWERS
AXIAL FANS - VAO SERIES
1. volumetric flowrate up to 10.000 m3/h
2. static pressure up to 8.000 mmH2O
3. installed power up to 500 kW
Advantage: Multi stage fans/blowers are a good technical and also commercial solution. Although the static efficiency is not very high, these solutions can be used instead of some centrifugal compressor, usually more expansive.
1. volumetric flowrate up to 700.000 m3/h
2. static pressure up to 1.000 mmH2O
3. iinstalled power up to 2.000 kW
Advantage: -Static efficiencies of 84% are obtained and noise levels are kept to a minimum. -The BCSN impeller is best suited for fluid with dusts maximum concentration of 100 mg/Nm3.
Turbofans type BDC are designed for very high pressure and low flow rate applications. Turbafans has a unique impeller innovative design (diameter of up to 2000 mm) which leads to static efficiencies up to 85%. By limiting the rotational speed, we allow for 15% energy savings in comparison with existing products in the market. The BDC impeller has 18 backwardly curved blades.
Turbofans type HP are designed for very high pressure and medium flow rate applications.By limiting the rotational speed, we allow for 15% energy savings in comparison with existing products in the market. The BDC impeller has 13 backwardly curved blades. Turbafans has a unique impeller innovative design (diameter of up to 2000 mm) which leads to static efficiencies up to 85%.